SEER2 Savings Calculator: Old AC vs a More Efficient System

Compare what your current central air conditioner costs to run each summer with a higher-SEER2 model, and see how long the extra price of the efficient unit takes to pay back.

Updated · Free, private: nothing you type leaves your browser.

SEER2 savings calculator

Your numbers

Roughly 600 in the North, 1,000–1,500 mid-South, 2,000+ in hot humid areas.

Older SEER ratings are roughly 4–5% higher than SEER2.

US average was 18.31¢ in July 2026 (EIA).

Your results

Moving from SEER2 10 to 16 cuts cooling costs from about $778 to $486 a year, a saving of $292.

Cooling cost now
$778
Cooling cost with new system
$486
Yearly savings
$292
Electricity saved
1,620 kWh
Payback on the extra cost
No extra cost entered

Estimate only. Uses the assumptions explained below.

How to use this calculator

  1. Enter the system size in tons (1 ton = 12,000 BTU per hour); it is often in the model number or on the outdoor unit's label.
  2. Enter your full-load cooling hours per year for your climate.
  3. Enter the SEER2 of the old system and of the new one you are considering.
  4. Add your electricity price and, if you want a payback, the extra cost of the more efficient model.

A higher SEER2 rating means a central air conditioner or heat pump uses less electricity for the same cooling. But a more efficient unit also costs more. This SEER2 savings calculator shows what the efficiency gain is worth in your climate and at your electricity price.

How the calculation works

SEER2 is cooling delivered (in BTU) per watt-hour of electricity over a season. So the electricity a system uses is the cooling it delivers divided by its SEER2.

Capacity (BTU/h)     = tons × 12,000
Seasonal cooling     = capacity × full-load hours
kWh used             = seasonal cooling ÷ (SEER2 × 1,000)
Cooling cost         = kWh used × electricity price
Yearly savings       = cost with old SEER2 − cost with new SEER2
Payback (years)      = extra cost of efficient model ÷ yearly savings

One ton of cooling is 12,000 BTU per hour. Dividing by 1,000 turns watt-hours into kWh.

The default price is $0.18 per kWh, from the July 2026 US average residential price of 18.31 cents (EIA, Table 5.6.A). The default 1,200 full-load hours is a mid-range assumption, not a measured value for your area.

The calculator assumes both systems deliver the same cooling over the same hours, and that each one performs at its rated SEER2. Real performance depends on installation, ducts and refrigerant charge.

Worked example

The default inputs: a 3-ton system, 1,200 full-load cooling hours, an old system at 10 SEER2, a new one at 16 SEER2, and $0.18 per kWh.

  1. Seasonal cooling: 3 × 12,000 × 1,200 = 43.2 million BTU.
  2. Old system: 43,200,000 ÷ (10 × 1,000) = 4,320 kWh, costing about $778 a year.
  3. New system: 43,200,000 ÷ (16 × 1,000) = 2,700 kWh, costing about $486 a year.
  4. Savings: about $292 a year and 1,620 kWh.

The default extra cost is $0, so the payback line reads “No extra cost entered”. Add the price difference between the two models to see a real payback.

A second example

A household in a hot climate has a 2.5-ton system rated 13 SEER2 and runs it about 2,000 full-load hours a year. They pay $0.155 per kWh. A 17 SEER2 replacement costs $1,500 more than a minimum-efficiency model. The calculator shows cooling costs falling from about $715 to $547 a year, a saving of about $168 and 1,086 kWh, and a payback on the extra cost of about 8.9 years.

What your result means

Yearly savings is what the efficiency gap is worth each cooling season at today’s price. Payback compares that with the extra price of the efficient model, not the whole system.

If you must replace a broken system anyway, compare models you could actually buy. The question is not “should I replace?” but “is the more efficient choice worth the extra cost?” A payback well inside the system’s expected life is a good sign. A payback longer than the life of the system usually is not, unless comfort features such as variable speed or better humidity control matter to you.

If your current system works, a big SEER2 jump alone rarely justifies replacing it early. Run the full project cost through the energy upgrade payback calculator to check.

How climate and SEER2 change the savings

Using the calculator’s defaults (3 tons, old system 10 SEER2, $0.18 per kWh):

ScenarioCost with old systemCost with new systemYearly savings
600 hours, new 16 SEER2$389$243$146
1,200 hours, new 14.3 SEER2$778$544$234
1,200 hours, new 16 SEER2 (default)$778$486$292
1,200 hours, new 18 SEER2$778$432$346
1,200 hours, new 20 SEER2$778$389$389
2,000 hours, new 16 SEER2$1,296$810$486

Notice that each step up in SEER2 saves a bit less than the step before. Going from 10 to 14.3 saves far more than going from 18 to 20. Hours of use matter as much as the rating.

Standards, incentives and local factors

Federal minimums. Since January 1, 2023, DOE requires split-system central air conditioners under 45,000 BTU per hour to reach 13.4 SEER2 in the North and 14.3 SEER2 in the Southeast and Southwest; split-system heat pumps must reach 14.3 SEER2 everywhere (DOE FAQ). DOE’s regional enforcement guidance says units that do not meet the regional standard cannot be installed in the Southeast or Southwest.

Tax credits. The federal 25C credit does not apply to property placed in service after December 31, 2025 (IRS). There is no federal tax credit for a new AC or heat pump installed in 2026. See our 2026 energy tax credit guide.

Rebates. State Home Energy Rebate programs run only in some states, and since DOE Program Notice 26-2 (effective May 29, 2026) heat pump rebates are limited to homes that already heat with electricity or new construction. Utility rebates vary. Check our rebates by state guide and DSIRE.

Electricity prices. In July 2026, average residential prices ranged from about 12.72 cents per kWh in Louisiana to 48.00 cents in Hawaii (EIA). The same efficiency upgrade is worth almost four times as much at the high end.

Common mistakes

  • Mixing SEER and SEER2. An old unit’s SEER label and a new unit’s SEER2 label are not the same scale. Convert the old one down slightly.
  • Using total run hours instead of full-load hours. Systems often run at part load, so full-load hours are lower than the hours the fan is on.
  • Counting the whole system price as “extra cost.” If you must replace the unit anyway, only the price difference between models belongs in the payback.
  • Ignoring installation quality. Leaky ducts, wrong refrigerant charge or poor airflow can erase the rated efficiency.
  • Oversizing. A system that is too big short-cycles. Ask for a Manual J load calculation, and see our heat pump cost and savings guide.

Limits of this calculator

The calculator uses rated SEER2 values and one average electricity price. It does not model part-load behavior, duct losses, humidity removal, time-of-use rates, aging equipment or future price changes. It covers cooling only, not heating.

It gives an educational estimate, not a quote or advice. Get at least three written quotes that list each model’s SEER2 rating and AHRI certificate number.

Questions people ask

What is SEER2?

SEER2 stands for Seasonal Energy Efficiency Ratio 2. It measures how much cooling a central air conditioner or heat pump delivers over a typical season for each watt-hour of electricity. Higher is better. The Department of Energy began using SEER2 on January 1, 2023, after changing the test procedure to better reflect real-world installations, such as the air resistance of typical ductwork.

How do I convert SEER to SEER2?

There is no exact conversion. The Department of Energy says SEER2 ratings are similar to the old SEER ratings but not directly comparable, because the test conditions changed. As a rough rule, this calculator's help text treats older SEER numbers as about 4 to 5 percent higher than SEER2. If your old unit is rated 10 SEER, entering about 9.5 SEER2 is a reasonable estimate.

What is the minimum SEER2 in 2026?

Federal standards that took effect January 1, 2023 still apply. Split-system central air conditioners under 45,000 BTU per hour must reach 13.4 SEER2 in the North and 14.3 SEER2 in the Southeast and Southwest, where they also need an EER2 rating. Split-system heat pumps must reach 14.3 SEER2 nationwide. A contractor cannot legally install a non-compliant central AC in the Southeast or Southwest.

Is a 16 SEER2 system worth it over a 14.3 SEER2?

It depends on how much you run your AC and on the price gap. With the calculator's defaults, a 3-ton system running 1,200 full-load hours at 18 cents per kWh costs about $544 a year at 14.3 SEER2 and $486 at 16 SEER2, a difference of about $58 a year. If the more efficient model costs $1,000 more, the calculator puts the payback at about 17.3 years. In hot climates with long cooling seasons, the case gets much stronger.

What are full-load cooling hours?

Full-load hours are the number of hours your system would need to run at full capacity to deliver a whole season of cooling. A system that runs at half power for 2,000 hours counts as about 1,000 full-load hours. The calculator suggests roughly 600 in the North, 1,000 to 1,500 in the mid-South and 2,000 or more in hot, humid areas as a starting point. Your utility or contractor may have local figures.

Is there a tax credit for a high-efficiency AC in 2026?

No. The federal Energy Efficient Home Improvement Credit (Section 25C) does not apply to property placed in service after December 31, 2025. Equipment installed in 2025 may still qualify on your 2025 tax return. Some utilities and states offer rebates; check DSIRE and your utility. Talk to a tax professional about your own situation.

Should I replace my AC with a heat pump instead?

If your AC is near the end of its life, a heat pump gives you the same cooling plus efficient heating. Its cooling cost at a given SEER2 is the same as an AC's, so this calculator covers the cooling side. To see what a heat pump could save on heating, use the heat pump savings calculator.

Sources

  1. 2023 Energy Conservation Standards for Central Air Conditioners and Heat Pumps: Frequently Asked Questions — U.S. Department of Energy, accessed
  2. Central Air Conditioner Regional Standards Enforcement Guidance — U.S. Department of Energy, accessed
  3. Electric Power Monthly, Table 5.6.A: Average Price of Electricity by State (July 2026) — U.S. Energy Information Administration, accessed
  4. FAQs for modification of sections 25C, 25D, 25E, 30C, 30D, 45L, 45W, and 179D under Public Law 119-21 — Internal Revenue Service, accessed
  5. Air Source Heat Pumps — ENERGY STAR (U.S. EPA and DOE), accessed
  6. Database of State Incentives for Renewables and Efficiency — NC Clean Energy Technology Center, NC State University, accessed

This calculator gives educational estimates, not quotes, tax advice or an eligibility decision. Results depend on the inputs and assumptions shown above. How we research